This space cannot be obstructed by baby changing tables or other fixtures or conveniences except as specified at 604 3 2 overlap.
Minimum non ada toilet stall dimensions.
Dimension guidelines when dispensers protrude from the wall in toilet rooms and toilet compartments.
However stall depth can be anywhere between 48 inches to 78 inches as needed.
An example of a single ada bathroom layout.
The room would be larger if the door were in swinging.
Anything that a person might need to reach should be a maximum of 48 1220 mm.
No more than 6 inches from inside corner.
Figure 30 a standard stall.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door.
The minimum width of the stall is 60 inches 1525 mm.
This plan shows a typical example of a single user toilet room that meets the minimum requirements of the 2010.
The minimum space required in toilet compartments is provided so that a person using a wheelchair can maneuver into position at the water closet.
Multiple toilet stall layouts.
Figure 30 a standard stall.
Partition stalls can have a minimum depth of 48 in most cases or up to 78 depth if needed.
The size of this room requires that the entry door swing out.
7 0 x 5 0 35 00 square feet.
56 inches inside clear for wall mounted toilets.
Generally stall doors open inward but for ada accessible stalls the doors should open outward to make it easier for those with accessibility.
The minimum width of the stall is 60 inches 1525 mm.
59 inches inside clear for floor mounted toilets.
60 inches minimum width of stall compartment inside clear stall depth.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
Distances should allow for common usage by people with a limited range of motion.
Standard toilet stalls are 36 wide by 60 depth.
You want to make sure you are measuring exactly where the partitions will be placed because bathrooms are not always exactly square.
The location of the door is in front of the clear space and diagonal to the water closet with a maximum stile width of 4 inches 100 mm.
At least 36 inches long.
2010 standards minimum with out swinging door.
There are many dimensions to consider when designing an accessible bathroom stall.